Power Transformers
We manufacture power transformers as per IS 2026, IS 6600, IEC 60076 & IS 1180 standards.
Power Transformer manufacturing range: Upto 10 MVA, 33kV
Method of cooling: Oil Natural Air Natural (ONAN)
Power transformer is applicable to Station & Multi-winding to suit specific needs & L.T. Transformers for generating Stations.
A Power transformer is an electrical device that transfers energy between two or more circuits through electromagnetic induction.
A varying current in the transformer's primary winding creates a varying magnetic flux in the core and a varying magnetic field impinging on the secondary winding. This varying magnetic field at the secondary induces a varying electromotive force (EMF) or voltage in the secondary winding. Making use of Faraday's Law in conjunction with high magnetic permeability core properties, transformers can thus be designed to efficiently change AC voltages from one voltage level to another within power networks.
Application in following industries :
Chemical, Pharmaceuticals, Steel, Textile, Engineering, Plastic, Cement, Refineries, Mining, Captive Power Projects, Hydro Power Projects, Wind Mill Farms, Construction Houses, Pharma, Electrical, Electronics, Renewable Energy, Automobiles.
Features:
• Robust design to take care of frequent short circuits.
• Manufactured with prime CRGO using step-lap design for low losses
• Windings made up of Copper or Aluminum manufactured using Strip (PICC or CTC) /Wire / Foil
• Step up and Step down transformers offered.
• Low noise levels
• Various rating Type-Tested for Short-Circuit, Impulse Voltage Withstand & Temperature Rise Tests at CPRI & ERDA.
Technical Specifications:
• Ratings: 3 phase upto 66 kV 10 MVA
• Frequency: 50/60 Hz
• Applicable Standards: Latest versions of IS:1180, IS:2026, IEC:60076, ANSI 57, BS, SANS 680
• Class of Insulation : A/B
• Cooling typically as ONAN (Oil Natural Air Natural)
• Vector Group: Any as per customer requirement like Dyn11, Yzn11, Dd0, etc.
• Insulating Fluid: Mineral Oil / Silicon Oil, both inhibited & inhibited, as per IS/IEC/ANSI/BS/SANS Standards
• Biodegradable Ester Filled Transformers also offered
• Standard Accessories as per customer specifications
Standard Fittings
1 Lifting Lug
2 Skid
Base / Roller Arrangement
3 Rating
and Diagram Plate
4 Earthing
Terminals
5 Primary
Bushings
6 Secondary
Bushings
7 Conservator
8 Oil
level Guage
9 Silica
gel Breather
10 Drain
/ Filter Valves
11 Thermometer
Pockets
12 Marshalling
Box
13 Inspection
Cover
14 Terminal
Connectors
15 Buchholz
Relay
16 Magnetic
Oil Level Guage
17 Winding
Temperature Indicator
18 Pressure
Relief Device / Explosion vent
19 Off
circuit Tap Switch /On load Tap Changer with RTCC & AVR
20 Siphon Thermo Filter